Kerosene heater

A modern Japanese kerosene heater

A kerosene heater, also known as a paraffin heater, is a portable, unvented, kerosene-fueled, space-heating device. In the United States they are used mainly for supplemental heat or as a source of emergency heat during a power outage.[1] In some countries, particularly in Japan, they are used as the primary source of home heat. Most kerosene heaters produce between 3.3 and 6.8 kW (11000 to 23000 BTU per hour).

Contents

  • Operation 1
  • Details of Operation 2
  • Odors of Operation 3
  • Safety Hazards 4
  • See also 5
  • References 6

Operation

A kerosene heater operates much like a large kerosene lamp. A circular wick made from fiberglass is integrated into a burner unit mounted above a font (tank) filled with 1-K kerosene. The wick draws kerosene from the tank via capillary action. Once lit, the wick emits flames into the burner unit which heats air via convection or nearby objects via radiation. The burner is designed to properly oxygenate and distribute the flames. The flame height is controlled by raising or lowering the exposed wick height inside the burner unit via an adjusting mechanism. The kerosene heater is extinguished by fully retracting the wick into a cavity below the burner, which will snuff out the flame. Efficiency is approx. 99%.

There has been a technological advance in kerosene heaters, some now use electricity to power a fan to force the heated air out, making it possible to heat up rooms faster. There is also thermostat controlled operation installed in modern kerosene heaters as well. However most kerosene heaters require no electricity to operate. Most heaters contain a battery-operated or piezo-electric ignitor to light the heater without the need for matches. If the ignitor should fail the heater can still be started manually.

The wicks require routine maintenance. With Fiberglass wicks, the kerosene heater is placed outdoors and allowed to operate until it runs out of fuel. Tar and other leftover deposits on the wick are burned off. This should be done at least once a week if operated 24hr a day. With Cotton wicks, you NEVER run the heaters dry to clean the wick. Cleaning is accomplished with a paper towel, wiping down the top of the wick to remove any "char". The wick will eventually deteriorate to the point where it will need to be replaced.

The Japanese non-vented "Fan" heater burns Kerosene gas and is known as a gasification type heater. The liquid Kerosene fuel is pre-heated via an electric heating element to vaporize the fuel. The resulting gas is collected and forced into the burn chamber where it is ignited and burns with a blue flame, similar to Propane. Output can be varied from 2500 Btu - max. The unit is fueled through a conventional side mount cartridge style tank just like other non-vented wick type radiant heaters. Efficiency is approx. 99%.

The other type of Japanese Kerosene heaters are the vented type with intake and exhaust piped through a dual pipe "chimney" through a side wall of a house. These units burn roughly like the old 1950's "pot" burners, but with fuel injection and computer control. Efficiency is approx. 87% - 89%.

Details of Operation

A kerosene heater is an appliance in which kerosene is gasified by surface evaporation and burned. The amount of kerosene evaporated and heat generated can be increased in direct proportion to the area of the contact surface between the kerosene and air. The wick used in a kerosene heater consists of many bundles of fine fibers and, in accordance with the principle behind it, it is designed to provide a large evaporation area. A wick consists of bundles of thin fibers and countless capillary tubes. The kerosene is drawn up from the tank into the combustion area by these capillary tubes. As a result, if the kerosene becomes viscous or dirt and dust find their way inside the heater, the capillary tubes will become clogged. This will cause a deterioration in the drawing of the kerosene and combustion will no longer be possible.[2]

Odors of Operation

When filling a kerosene heater, there is an opportunity for the fuel to vaporize and create an odor in the air. This is why it is important to fill the heater in a garage or outdoors. When a kerosene heater is first ignited, it takes a few seconds to a few minutes for the fuel to mix with the air in the perfect ratio for complete combustion. For that space of time, the fuel to air mixture is quite rich. This results in a small amount of unburned kerosene. Once the heater is burning normally, no additional odor is created. An improperly adjusted wick causes smoke and odor.[3] This is corrected by adjusting the wick-height. A wick with carbon build-up will also cause odor. A wick in this condition should be replaced. Odor may also be apparent when the heater is extinguished. The wick holder remains quite warm. When lowered, the wick continues to draw kerosene, causing a vaporization of the fuel which is detected as odor.

Safety Hazards

Because kerosene heaters are usually unvented, all combustion products are released into the indoor air. Among these are low levels of

  1. ^ http://indoorkeroseneheater.org/
  2. ^ http://www.rentequip.com/pub/KeroseneManual.pdf
  3. ^ http://www.rentequip.com/pub/KeroseneManual.pdf
  4. ^ http://www.cpsc.gov/cpscpub/pubs/5052.html
  5. ^ http://indoorkeroseneheater.org/
  6. ^ http://www.cpsc.gov/cpscpub/pubs/5052.html

References

See also

Always use clear 1-K Kerosene if available. The pink "off road" Kerosene can be burned in the Fiberglass wicked models as well as the Japanese vented heaters. The Japanese "gasification" type as well as all the cotton wicked heaters should use clear K1. Use of impure fuel can cause extra soot. A risk of explosion is present with even trace amounts of gasoline mixed in the fuel, which is why it is illegal in many jurisdictions to dispense gasoline into unauthorized containers such as kerosene jugs; be sure to store in a container that has not been used with gasoline.[6]

Hot surfaces on the heater pose a fire and burn risk. The open flame poses an explosion risk in environments where flammable vapors may be present, such as in a garage. Use of improper or contaminated fuel could cause poor performance, a fire or an explosion. There are the usual risks involved with the storage of kerosene and when refilling the heater.

. carbon monoxide poisoning or asphyxiation Failure to follow these precautions could result in [5]

This article was sourced from Creative Commons Attribution-ShareAlike License; additional terms may apply. World Heritage Encyclopedia content is assembled from numerous content providers, Open Access Publishing, and in compliance with The Fair Access to Science and Technology Research Act (FASTR), Wikimedia Foundation, Inc., Public Library of Science, The Encyclopedia of Life, Open Book Publishers (OBP), PubMed, U.S. National Library of Medicine, National Center for Biotechnology Information, U.S. National Library of Medicine, National Institutes of Health (NIH), U.S. Department of Health & Human Services, and USA.gov, which sources content from all federal, state, local, tribal, and territorial government publication portals (.gov, .mil, .edu). Funding for USA.gov and content contributors is made possible from the U.S. Congress, E-Government Act of 2002.
 
Crowd sourced content that is contributed to World Heritage Encyclopedia is peer reviewed and edited by our editorial staff to ensure quality scholarly research articles.
 
By using this site, you agree to the Terms of Use and Privacy Policy. World Heritage Encyclopedia™ is a registered trademark of the World Public Library Association, a non-profit organization.
 



Copyright © World Library Foundation. All rights reserved. eBooks from World Library are sponsored by the World Library Foundation,
a 501c(4) Member's Support Non-Profit Organization, and is NOT affiliated with any governmental agency or department.